Inspection_1
Inspection_2

Industry Sector

Pulp & Paper

Project Type

Inspection of radial blower – in situ balancing

Equipment type

Airflow: 1200 m³/h

Pressure Increase (Δp): 40 mbar

Speed: 2950 rpm

Power: 2.2 kW

Location: Germany

Equipment brand

FIMA

Project Scope

Description
Blower is experiencing high vibrations 7.5mm/s– since installation no inspection of revision of blower

 

Services Performed
Cleaning and visual inspection of radial blower – in situ balancing, functional testing

 

Challenges
Successful balancing

 

Outcome
Blower runs perfectly. Client confirmed that vibration levels are lower than after blower delivery and installation!

 

Date / Duration
Week 03 / 2024 – 1 working day